ASACLEAN grade · specific

ASACLEAN UPDedicated grade for PP jobs

Standard grade for PP jobs, PE-compatible per terms

UP is the standard grade for PP while newUP targets low residue. Check purge order and limits per real job

Download TDSCompare all grades
170–300°COperating temperature
Definition & positioning

What jobs fits UP

Standard grade for PP jobs, PE-compatible per terms. Use for color change, material change and machine sealing in olefin jobs — verify TDS limits before use

Process
Injection including Hot Runner; profile/sheet/blown film/compounding
Resin
PP; also usable with PE
Temperature
170–300°C
Objectives
Color change, material change and machine sealing in olefin jobs
Hot Runner
Compatible with minimum 0.5 mm clearance
Glass Fiber / Additives
Glass-fiber-free; TDS notes inorganic additives below 40%
Machine Sealing
Machine sealing compatible
Residence / Clearance
No screen finer than 100 mesh; max 30 min residence above 280°C
Strengths

Grade strengths

Primary pick for PP, covering many processes

Use cases

Color change, material change and machine sealing in olefin jobs

Constraints

Limits before use

UP is the standard grade for PP while newUP targets low residue. Check purge order and limits per real job

Check on site: Temperature, resin type, Hot Runner, clearance, screen mesh and residence time
Basic operation

Basic usage

  1. Confirm UP resin and temperature
  2. Purge old resin and set the machine per TDS, observing: no screen finer than 100 mesh; max 30 min residence above 280°C
  3. Feed purging compound; adjust back pressure and screw speed to machine state
  4. Chase purging compound out with next resin; verify cleanliness before production

Injection purging procedure · Extruder guide · Back Pressure and Screw Speed

Technical documents

The TDS is the authoritative document for temperature range, process and limits

UP FAQ

At what temperature does UP run

The confirmed range for UP is 170–300°C

Can UP run Hot Runner

Compatible with minimum 0.5 mm clearance

Can UP seal machines

Machine sealing compatible

Plan a controlled trial for UP

CSC technicians verify terms, set the baseline and define pass criteria

LINE

Match grade to PP jobs

See how to select purging compound for PP Compare roles of UP, newUP and CP before checking the TDS of the selected grade

LINE