ASACLEAN grade · specific

ASACLEAN CPValue pick for PP jobs

Olefin-base purging compound for PP/PE, cost per terms

Check resin, temperature, Hot Runner and limits before substituting other grades

Download TDSCompare all grades
170–300°COperating temperature
Definition & positioning

What jobs fits CP

Olefin-base purging compound for PP/PE, cost weighed per terms. Use for color change, material change and machine sealing — verify TDS limits before use

Process
Injection including Hot Runner; profile/sheet/blown film/compounding
Resin
PP; usable with PE; olefin-based
Temperature
170–300°C
Objectives
Color change, material change and machine sealing
Hot Runner
Compatible with minimum 0.5 mm clearance
Glass Fiber / Additives
Glass-fiber-free; TDS notes inorganic additives above 40%
Machine Sealing
Machine sealing compatible
Residence / Clearance
No screen finer than 100 mesh; max 30 min residence above 280°C
Strengths

Grade strengths

Qualifies as a lower-cost option when all terms pass

Use cases

Color change, material change and machine sealing

Constraints

Limits before use

Check resin, temperature, Hot Runner and limits before substituting other grades

Check on site: Temperature, resin type, Hot Runner, clearance, screen mesh and residence time
Basic operation

Basic usage

  1. Confirm CP resin and temperature
  2. Purge old resin and set the machine per TDS, observing: no screen finer than 100 mesh; max 30 min residence above 280°C
  3. Feed purging compound; adjust back pressure and screw speed to machine state
  4. Chase purging compound out with next resin; verify cleanliness before production

Injection purging procedure · Extruder guide · Back Pressure and Screw Speed

Technical documents

The TDS is the authoritative document for temperature range, process and limits

CP FAQ

At what temperature does CP run

The confirmed range for CP is 170–300°C

Can CP run Hot Runner

Compatible with minimum 0.5 mm clearance

Can CP seal machines

Machine sealing compatible

Plan a controlled trial for CP

CSC technicians verify terms, set the baseline and define pass criteria

LINE

Match value to PP jobs

Compare PP grades Weigh quality, time and actual purging-compound usage together

LINE