ASACLEAN grade · general

RUASACLEAN purging compound

R-Series for color and material changes, with Hot Runner support

Confirm clearance and residence time per TDS

Download TDSCompare all grades
180–330°COperating temperature
Definition & positioning

What jobs fits RU

R-Series for color and material changes, with Hot Runner support. Use for color change, material change and machine sealing — verify TDS limits before use

Process
Injection including Hot Runner; extrusion compounding/profile
Resin
General-purpose resins and most engineering plastics
Temperature
180–330°C
Objectives
Color change, material change and machine sealing
Hot Runner
Compatible with minimum 0.5 mm clearance
Glass Fiber / Additives
Glass-fiber-free
Machine Sealing
Machine sealing compatible
Residence / Clearance
No screen finer than 100 mesh; max 30 min residence above 280°C
Strengths

Grade strengths

High cleaning power with broad use, Hot Runner included

Use cases

Color change, material change and machine sealing

Constraints

Limits before use

Confirm clearance and residence time per TDS

Check on site: Temperature, resin type, Hot Runner, clearance, screen mesh and residence time
Basic operation

Basic usage

  1. Confirm RU resin and temperature
  2. Purge old resin and set the machine per TDS, observing: no screen finer than 100 mesh; max 30 min residence above 280°C
  3. Feed purging compound; adjust back pressure and screw speed to machine state
  4. Chase purging compound out with next resin; verify cleanliness before production

Injection purging procedure · Extruder guide · Back Pressure and Screw Speed

Technical documents

The TDS is the authoritative document for temperature range, process and limits

RU FAQ

At what temperature does RU run

The confirmed range for RU is 180–330°C

Can RU run Hot Runner

Compatible with minimum 0.5 mm clearance

Can RU seal machines

Machine sealing compatible

Plan a controlled trial for RU

CSC technicians verify terms, set the baseline and define pass criteria